Elbit Filmed Green Phosphor Image Tube
TEST MINIMUM MAXIMUM
Center Resolution (lp/mm) 64
FOM 1344
Signal to Noise 21
Spots PASS
Elbit Filmed Green Phosphor Image Tube
Spot Size Zone 1 Zone 2 Zone 3
(Inches) Limit Limit Limit
>.015 0 0 0
>.012-.015 0 0 0
>.009-.012 0 1 1
>.006-.009 0 1 2
.003-.006 1 2 3
No more than 5 spots will be allowed
Elbit Filmed White Phosphor Image Tube
TEST MINIMUM MAXIMUM
Center Resolution (lp/mm) 64
FOM 1344
Signal to Noise 21
Spots PASS
Elbit Filmed White Phosphor Image Tube
Spot Size Zone 1 Zone 2 Zone 3
(Inches) Limit Limit Limit
>.015 0 0 0
>.012-.015 0 0 0
>.009-.012 0 1 1
>.006-.009 0 1 2
.003-.006 1 2 3
No more than 5 spots will be allowed
L3 Unfilmed White 18UM Image Tube
TEST MINIMUM MAXIMUM
Signal to Noise 24
Center Resolution 64
Figure of Merit (FOM) 1536
L3 Unfilmed White 18UM Image Tube
Spot Size Zone 1 Zone 2 Zone 3
(Inches) Limit Limit Limit
>.012 0 0 0
>.009 0 0 0
>.006-.009 0 1 1
>.003-.006 0 2 2
Bright Spots 0 0 0
Dark spots </= .003” are acceptable
L3 Unfilmed White 20UM Image Tube
TEST MINIMUM MAXIMUM
Signal to Noise 28
Center Resolution 64
Figure of Merit (FOM) 1792
L3 Unfilmed White 20UA Image Tube
Spot Size Zone 1 Zone 2 Zone 3
(Inches) Limit Limit Limit
>.012 0 0 0
>.009 0 0 0
>.006-.009 0 0 1
>.003-.006 0 0 2
Bright Spots 0 0 0
Dark spots </= .003” are acceptable
L3 Unfilmed White 20UA Image Tube
TEST MINIMUM MAXIMUM
Signal to Noise 28
Center Resolution 64
Figure of Merit (FOM) 1792
L3 Unfilmed White 20UA Image Tube
Spot Size Zone 1 Zone 2 Zone 3
(Inches) Limit Limit Limit
>.012 0 0 0
>.009 0 0 0
>.006-.009 0 0 1
>.003-.006 0 0 2
Bright Spots 0 0 0
Dark spots </= .003” are acceptable
L3 Unfilmed White 22UA Image Tube
TEST MINIMUM MAXIMUM
Signal to Noise
Center Resolution 64
Figure of Merit (FOM) 1920

 

L3 Unfilmed White 22UA Image Tube
Spot Size Zone 1 Zone 2 Zone 3
(Inches) Limit Limit Limit
>.012 0 0 0
>.009 0 0 0
>.006-.009 0 0 1
>.003-.006 0 0 2
Bright Spots 0 0 0
Dark spots </= .003” are acceptable