SI/ DTNVS-MG L3 Unfilmed White Phosphor

SKU: ACT-DTNVS-MG-L3-WP-RTS Category:
ITAR
This product is regulated by ITAR. It can only be shipped in the USA

This product is currently out of stock and unavailable.

WHAT’S INCLUDED?

One SI/DTNVS-MG  Night Vision Goggle; four lens caps; Steele Industries hard case; warranty card; quality control report; spec sheets.

TUBE SPECS

Our SI/DTNVS-MG Goggle has the specs for the image intensifier listed in the drop down variation menu. If you do not understand the specs, and would like assistance please give us a call, or join our live chat and we will be more than happy to assist in options.

Common Terminology:

FOM (Figure of Merit)

Image Intensification tube specification designation, calculated on line pair per mm x signal to noise.

Center Resolution

The ability of an image intensifier or night vision system to distinguish between objects close together. Image intensifier resolution is measured in line pairs per millimeter (lp/mm) while system resolution is measured in cycles per miliradian. For any particular night vision system, the image intensifier resolution will remain constant while the system resolution can be affected by altering the objective or eyepiece optics by adding magnification or relay lenses. Often the resolution in the same night vision device is very different when measured at the center of the image and at the periphery of the image. This is especially important for devices selected for photograph or video where the entire image resolution is important. Measured in line pairs per millimeter (lp/mm).

SNR (Signal to Noise Ratio)

A measure of the light signal reaching the eye divided by the perceived noise as seen by the eye. A tube’s SNR determines the low light resolution of the image tube; therefore, the higher the SNR, the better the ability of the tube to resolve objects with good contrast under low-light conditions. Because SNR is directly related to the photocathode’s sensitivity and also accounts for phosphor efficiency and MCP operating voltage, it is the best single indicator of an image intensifier’s performance

EBI (Equivalent Background Illumination)

This is the amount of light you see through a night vision device when an image tube is turned on but no light is on the photocathode. EBI is affected by temperature; the warmer the night vision device, the brighter the background illumination. EBI is measured in lumens per square centimeter (lm/cm2). The lower the value the better. The EBI level determines the lowest light level at which an image can be detected. Below this light level, objects will be masked by the EBI.

HALO 

Halo is the circular region around a bright light that appears “brighter” – It’s caused by elastic collisions of electrons with the MCP surface which subsequently then bounce off and down another hole. Halo’s are the same size all over the screen and the size is dictated by the distance between the photocathode and the MCP. Basically, it’s the round circle around lights when you look at them with Night Vision and it’s generally used as an indication that you’re looking at something that’s too bright.

Photocathode Sensitivity 

Photocathode sensitivity is a measure of how well the image intensifier tube converts light into an electronic signal so it can be amplified. The measureing units of photocathode sensitivity are micro-amps/lumen (µA/lm) or microamperes per lumen. This criterion specifies the number of electrons released by the Photocathode (PC). PC response is always measured in isolation with no amplification stage or ion barrier (film). Therefore, tube data sheets (which always carry this “raw” figure) do not reflect the fact that over 50% of those electrons are lost in the ion barrier. While for most latest 3rd generation image intensifiers the photoresponse is in the 1800 µA/lm (2000 µA/lm for the latest Omni VI Pinnacle tubes), the actual number is more like 900 µA/lm.

Luminance Gain

Also called brightness gain or luminance gain. This is the number of times a night vision device amplifies light input. It is usually measured as tube gain and system gain. Tube gain is measured as the light output (in fL) divided by the light input (in fc). This figure is usually expressed in values of tens of thousands. If tube gain is pushed too high, the tube will be “noisier” and the signal-to-noise ration many go down. U.S. military Gen 3 image tubes operate at gains of between 20,000 and 45,000. On the other hand, system gain is measured as the light output (fL) divided by the light input (also fL) and is what the user actually sees. System gain is usually seen in the thousands. U.S. military systems operate at 2,000 to 3,000. In any night vision system, the tube gain is reduced by the system’s lenses and is affected by the quality of the optics or any filters. Therefore, system gain is a more important measurement to the user.

SPECIFICATIONS

Features:

  • New front plate design
    • Direct screw inserts to attach IPD module
    • Manual Gain support for all tube manufacturers and manual gain tube types
    • Adjustable IR Output
    • 10 year warranty and limited lifetime service

You may also like…

  • Sale! 20231214 095711000 iOS

    Wilcox L4 G24 Mount

    Original price was: $527.98.Current price is: $500.98.
  • Sale! 20231214 093931070 iOS

    Night Vision Helmet Retention Harness

    Original price was: $24.98.Current price is: $9.98.
  • Sale! 20231215 085409390 iOS